Roof Dew Point Calculation

The dew point temperature occurs at the intersection of the design dry bulb temperature column and the rh row.
Roof dew point calculation. In this example the dew point temperature is 49 f i e. According to nrca dew point calculations are necessary whenever the outside average january temperature is below 4 c 40 f and when the expected interior winter rh is 45 percent or greater. Let s consider miami and phoenix again as two extremes. In this working example 75 f i e.
Dew point varies depending on the amount of water vapor present in the air with more humid air resulting in a higher dew point than dry air. Determine the winter interior design dry bulb temperature. The dew point temperature determines what combinations of temperature and rh will be possible in the storage environment. The dew point is a specific temperature at a given humidity at which water vapor condenses.
That gives you a dew point of about 50 f according to the chart at above left. What s a dew point calculation. Obviously a lot of condensation will form on a chilled beverage glass. Design values can be found in chapter 14 climatic design.
This design value is essentially the temperature that. At a constant dew point when the temperature goes up the rh goes down and when the temperature goes down the rh goes up. To be conservative assume an indoor relative humidity of 50 percent at 70 f. First you need to calculate the dew point of the interior air during the winter.
4 c is specifically listed as a relative humidity so no linear interpolation is necessary. Or see dew point calculation for walls for making more precise dew point calculations. In the summer miami s relative humidity can reach 85 at a temperature of 80 f. Furthermore the higher the relative humidity the closer the dew point to the current air temperature with 100 relative humidity meaning that dew point is equivalent to the current temperature.
Obtain the winter exterior design dry bulb temperature. How to calculate the dew point more precisely e0 0 611 kpa l rv 5423 k in kelvin over a flat surface of water t0 273 k kelvin t temperature in kelvin td the dew point temperature in kelvin. Builders or designers perform dew point calculations to determine whether a certain component of a wall ceiling or roof in most cases the sheathing will stay warm enough during the winter to avoid condensation problems. 22 88 c is the dry bulb interior temperature and 40 f i e.
Draw the roof assembly to a practical. The national roof contractors association nrca map.